We serviced a
WHIRLPOOL REFRIGERATOR
Model KRMF706EBS05
Near Woodsboro, MD 21798
Justin S.
Job Details: 07/20/2022
"the unit is cooling good. didnt hear the noise. replaced the compressor and vacuummed down the system. filled to weight and checked for leaks. the unit is now cooling good. the unit is good; ordrng 1 w10890124 (coupler) and 1 w10891058 (coupler) and 1 w10890087 (coupler) and 2 w10890121 (coupler)s and 1 w10890117 (coupler) and 1 w10891057 (coupler) and 1 w10843121 (dryer) and 1 w10913906 (coupler), used 1 w10890124 (coupler), 1 w10891058 (coupler), 1 w10890087 (coupler), 2 w10890121 (coupler), 1 w10890117 (coupler), 1 w10891057 (coupler), 1 w10843121 (dryer), and 1 w10913906 (coupler) from stock"
We serviced a
WHIRLPOOL DISHWASHER
Model WDT750SAHZ0
Near Woodsboro, MD 21798
Ricky E.
Job Details: 07/06/2022
5-1 2-1 customer stated that the unit wasnt washing. verified issue and fnd comm issues from the ui and control. also the unit is loosing pressure in the sump and the dispenser doors will not stay closed and have faulty latches... need parts..; ordrng 1 W11192367 (console) and 1 W10861000 (detergent dispenser)
We serviced a
WHIRLPOOL RANGE
Model n/a
Near Woodsboro, MD 21798
Brian R.
Job Details: 07/05/2022
cx complaint is unit does not heat or hold temp. he had unit tore apart. took both elements somewhere to get checked as well as sensor and back fan and all. sticker info wore off and no numbers on unit to pull up info. advised cx we need info or we cant do anything. only thing he knows is its old. cx will need to try and find info so we can look unit up and for parts. he will pay service for today.
We serviced a
WHIRLPOOL REFRIGERATOR
Model KRMF706EBS05
Near Woodsboro, MD 21798
Brian R.
Job Details: 06/09/2022
cx complaint is noise is still there at times. puklled unit to check lines and hitting back cover. no sounds now. put unit back and turned cooling off and opened doors for 5-10 min to turn back on and unit kick on as a higher start up to check sound. unit was put back and not level and a slist twist. found noise from compressor. depending of how you moved it the sound was louder. called tech line and spoke to Rick and 7733848684 tested and checked unit to find noise and vibration coming from compressor and the compressor needs to replaced. as soon as part is in office will schedule. also ordered lock ring kit for return.; ordrng 1 W11578205 (Compressor) and 1 LockRingKit (Lock Ring Kit)
We serviced a
WHIRLPOOL REFRIGERATOR
Model KRMF706EBS05
Near Woodsboro, MD 21798
Brian R.
Job Details: 06/09/2022
cx complaint is noise is still there at times. puklled unit to check lines and hitting back cover. no sounds now. put unit back and turned cooling off and opened doors for 5-10 min to turn back on and unit kick on as a higher start up to check sound. unit was put back and not level and a slist twist. found noise from compressor. depending of how you moved it the sound was louder. called tech line and spoke to Rick and 7733848684 tested and checked unit to find noise and vibration coming from compressor and the compressor needs to replaced. as soon as part is in office will schedule. also ordered lock ring kit for return.; ordrng 1 W11578205 (Compressor) and 1 LockRingKit (Lock Ring Kit)