Appliance Repair Woodlawn Maryland

VIA INC Rated out of 5 stars based on customer reviews

We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT313CZLZ00
Near Woodlawn, MD 21244
Shane M.
Job Details: 09/29/2023
"cx complaint tthe unit leaking inside unit, found evap drained clogged. cleared ice, cleared drainhole, unit working properly."
We serviced a
WHIRLPOOL DRYER
Model WGD8127LC3
Near Woodlawn, MD 21244
Shane M.
Job Details: 09/28/2023
"cx complaint the unit isnt heating properly. found when testing unit, unit heats but making loud noises. found vent exit clogged with lint. cleared vent, airflow is now good, drive motor is whinning. ordering drive motor blower wheel pulley and belt.; ordrng 1 WP697772 (blower wheel) and 1 W10837240 (pulley) and 1 W11549461 (drive motor) and 1 661570V (belt)"
We serviced a
MAYTAG WASHER
Model MVW4505MW0
Near Woodlawn, MD 21207
Marc M.
Job Details: 09/25/2023
cx complaint unit not completing cycle. inspected unit and found error f7e1 tach missing or wrong sginal. ran auto test cycle and unit DID both agitate and spin. possible intermitent issue.; ordrng 1 W11481722 (shifter) and 1 W11626074 (control)
We serviced a
MAYTAG WASHER
Model MVW7230HW0
Near Woodlawn, MD 21207
Emmanuel R.
Job Details: 09/18/2023
"Replaced gearcase and slider, tested all other components , unit is now working as designed. No error codes ,test cycle passed."
We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Woodlawn, MD 21207
Dustin F.
Job Details: 09/13/2023
"cx complaint: unit died not workingInspected unit, confirmed cx complaint. had to pry open door latch to access model serial. CX gave me permission to get it open. Checked and confirmed 121v at wall. 121v comming into control but only 3.5 dc volts comming from control to console. unit needs new control"