Appliance Repair Wakefield Virginia

VIA INC Rated out of 5 stars based on 0 customer reviews

We serviced a
WHIRLPOOL FREEZER
Model WRS325SDHB04
Near Wakefield, VA 23888
Lucas R.
Job Details: 03/03/2023
"replaced control, heater did not come on, after 15 min run time still no frost pattern, replaced compressor drier and evap, pressurized, no visible leaks, vacuumed and charged, low pressure at 0, frost pattern forming, unit working as designed."
We serviced a
WHIRLPOOL FREEZER
Model WRS325SDHB04
Near Wakefield, VA 23888
Lucas R.
Job Details: 03/03/2023
"replaced control, heater did not come on, after 15 min run time still no frost pattern, replaced compressor drier and evap, pressurized, no visible leaks, vacuumed and charged, low pressure at 0, frost pattern forming, unit working as designed."
We serviced a
WHIRLPOOL FREEZER
Model WRS325SDHB04
Near Wakefield, VA 23888
Lucas R.
Job Details: 02/23/2023
"upon arrival both compartments room temp, evap compartment hot, heater energized, all thermistors reading 3.2-3.4k ohms, reset unit compressor runs for 2 min then shuts down cooling, and energizes defrost heater, called techline spoke with rit sr7735804311, advised to replace relay board, called parts ordering, cost breakdown control W11449482 $112.87 thermistor not needed, $-64.88 labor $110.00, collected $157.99, scheduled for 2-28-28; ordrng 1 W11449482 (control)"
We serviced a
WHIRLPOOL FREEZER
Model WRS325SDHB04
Near Wakefield, VA 23888
Zachery R.
Job Details: 02/09/2023
"cx complaint no cool, checked unit, fc at 55 degrees, rc at 60 degrees. compressor reading .8amps, thermistor reading 31k ohms. evap only has a partial frost pattern. unplugged evap fan, waited 10 mins for frost pattern to form. unit would not form good frost pattern, spoke with AR, quoted cx W10507884 compressor, WPW10143759 dryer , W11506635 coupler , WP2188823 evap, thermistor WPW10384183. cx unsure for repair at this time. cx paid $120"