We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT311FZDW02
Near Shillington, PA 19607
Justin L.
Job Details: 07/27/2023
Was able to access unit and hooked up my gauges and found system empty. Charged with nitrogen and found leak from discharge line. Vacuumed down and sealed. Revacuumed and charged with 47 g R600. Watched as evap built a frost pattern unit now checks good no further work needed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT311FZDW02
Near Shillington, PA 19607
Justin L.
Job Details: 07/07/2023
Was able to access unit and cut into system to find a full charge. Removed and replaced compressor and filter drier. Pulled unit into vacuum and charged with 47 g R600. Unit began to develop frost pattern. unit now checks good no further work needed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT318FZDB09
Near Shillington, PA 19607
Justin L.
Job Details: 06/20/2023
Was able to access unit and while cutting into system cap tube fell out of the liner. Was unable to find any extra cap tube poking out and found that to be cause of the leak. Contacted techline and spoke to Nate SR#7736676355 unit is unrepairable. Cx will need to reach out to tradecare for next steps no further work needed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT318FZDB09
Near Shillington, PA 19607
Justin L.
Job Details: 06/09/2023
Cx complaint unit not cooling. Was able to access unit and found plugged in with lights on all fans and compressor running. Removed evap cover to find no frost pattern. Unit will need 3 call count sealed system repair. Once parts are in office will need to contact cx to set return; ordrng 1 W11562258 (evaporator) and 1 W11504419 (evap coupler) and 1 W11504449 (evap coupler) and 1 W11109499 (drier) and 1 W11582579 (compressor) and 3 W11506635 (process stub)s and 1 876765 (tubing kit)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT311FZDW02
Near Shillington, PA 19607
Cody H.
Job Details: 05/25/2023
"CX complains unit is not cooling. Found unit to be warm in both FC and RC. Unit shows no frost pattern but compressor is humming. Compressor is drawing .27 amps. Called FG with findings who said to order compressor, drier, and evap as well as 3XL. Office to reach out to CX when all parts arrive.; ordrng 1 W11578004 (evap) and 1 W11504450 (cap to vap lockring) and 2 W11506619 (evap lock ring)s and 1 W11580057 (compressor) and 2 W11506619 (compressor lock ring)s and 1 W11578570 (high to condenser lockring) and 2 W11109499 (drier)s and 1 W11504445 (drier lock ring 1) and 1 W11504447 (drier lock ring 2)"