Appliance Repair Riva Maryland

VIA INC Rated 5.0 out of 5 stars based on 2 customer reviews

We serviced a
WHIRLPOOL WASHER
Model WFW97HEXL2
Near Riva, MD 21140
Andrew H.
Job Details: 07/14/2022
Customers complaint is the unit is leaking water. I inspected unit found a tear in the Bellow gasket. I replaced Bello gasket and tested unit. Unit is not working properly
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRB329DMBM00
Near Riva, MD 21140
Andrew H.
Job Details: 06/21/2022
Cx complaint is the unit is not cooling. I found the low side at -22 psi and 125psi on the high side. I found unit unit does not have signs of a leak. I could not find die anywhere in the unit both compressor area and evaporator area. I reclaimed refrigerant from the unit and filled unit to 140 PSI and nitrogen. Unit held nitrogen at 140 PSI for 20 minutes. I replace the dryer pulled unit into a 30-in vacuum. And filled unit to 4.25 Oz. Unit is now building a full Frost pattern and is now working properly.
We serviced a
WHIRLPOOL WASHER
Model WFW97HEXL2
Near Riva, MD 21140
Kevin P.
Job Details: 06/08/2022
"cx complaint unit has water sitting in fold of bellow not draining back into the tub properly and door is sagging not closing properly, adjusted door hinge that came loose letting the door sag and cleared blockages that built up in the bellow. job complete."
We serviced a
WHIRLPOOL WASHER
Model WFW97HEXL2
Near Riva, MD 21140
Kevin P.
Job Details: 06/08/2022
"cx complaint unit has water sitting in fold of bellow not draining back into the tub properly and door is sagging not closing properly, adjusted door hinge that came loose letting the door sag and cleared blockages that built up in the bellow. job complete."
We serviced a
JENNAIR ICE MAKER
Model JUIFX15HX00
Near Riva, MD 21140
Shawn D.
Job Details: 05/27/2022
cx complaint inside of unit got warm and ice cubes were very small and very little ice was being made. inspected unit and is off so turned it on and ran diagnostics unit seems to be filling slow with water pump came on to put water on evap plate and pump is running dry to amount of water in it. pullled unit out on matt and checked water pressure and is great. removed filter and ran diagnostics again and now unit if filling fast with water and filled to good amount and pump did not run dry. let unit run in normal opperations and started freezing water on plate. when over use and care with cx to run clean cycle once a month or eveything 3 depending on how much she uses and understands. unit is good