Appliance Repair New Cumberland Pennsylvania

VIA INC Rated out of 5 stars based on 0 customer reviews

We serviced a
WHIRLPOOL FREEZER
Model WZF34X20DW02
Near New Cumberland, PA 17070
Sal R.
Job Details: 10/21/2022
"Per the previouse tech, I was able to access and replace the thermisote. Informed CX to allow a min of 24hr's before unit returns to reccomended temps."
We serviced a
WHIRLPOOL FREEZER
Model WZF34X20DW02
Near New Cumberland, PA 17070
Fred G.
Job Details: 07/21/2022
"cx complaint freezing stop working. inspected unit and found large gap at the bottom of the freezer door gasketr. inspected door and found bottom of door is warpped. unit needs new door and a defrost. ordering 1 (W11178521), 1 (W10746789). advised cx door will ship to them and takes 4- 6 weeks. once in to open box and check for damage. once it looks good cx will call and schedule apt.; ordrng 1 W10746789 (dor-fmd) and 1 W11178521 (nameplate) and 1 W11501317 (gasket)"
We serviced a
WHIRLPOOL RANGE
Model WFG550S0HZ2
Near New Cumberland, PA 17070
Bernard M.
Job Details: 07/20/2022
"Cx complaint of the flames too high and flames coming out from under cooktop. When arrived ignited all burners and all adjusted from high to low flames. Cx stated when igniting right rear she can smell gas and flames shot out from under cooktop. Removed front panel and with burner is on, could smell gas coming from assembly. Reported to WP safety and ordering right rear orifice holder. Once part is in contact cx to reschedule SR#7734131686; ordrng 1 W11453921 (orifice holder (RR))"
We serviced a
WHIRLPOOL DRYER
Model WED9150WW0
Near New Cumberland, PA 17070
Drew B.
Job Details: 07/15/2022
cx complaint that unit is making loud screeching noise when running the unit the unit heats and runs but makesn oise the unit is stacked in a closet in a bathroom with bar above hand.. will need 2 tech to gain access to unit for repair call when 2 tech is able.. parts will need on return.; ordrng 1 2tech (2 tech)
We serviced a
N/A N/A
Model MEDX500XL0
Near New Cumberland, PA 17070
Drew B.
Job Details: 07/15/2022
cx complaint that unit is not heat at all and when arrived power had 240/120 @wall to block.. then checked power at the element and had 240 at the element prongs. found the unit to have open element.. will need the following parts call to reschd when in and approved; ordrng 1 3387747 (element) and 1 8318314 (cutoff-tml)