Appliance Repair Millsboro Delaware

VIA INC Rated 5.0 out of 5 stars based on 2 customer reviews

We serviced a
JENNAIR OVEN
Model JDS1750ES0
Near Millsboro, DE 19966
Frederick R.
Job Details: 07/21/2022
"CX complaint is oven not heating. Tested and verified CX complaint. Found the bake element to be shorted and burnt. Replaced element from pre-id. Charged CX $308.68 for SC, labor, part and shipping. CX paid in full. Retested oven and it is now working properly. Job is complete"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS555SIHZ06
Near Millsboro, DE 19966
Frederick R.
Job Details: 07/21/2022
CX complaint is unit a no cool. Replaced compressor and drier. While I was brazing the return line back on I ran out of acetyline gas and couldnt finish brazing. CX is rescheduled for this Saturday to finish job and fill unit.; saved tckt
We serviced a
WHIRLPOOL DRYER
Model MEDC465HW0
Near Millsboro, DE 19966
Andrew W.
Job Details: 07/21/2022
cx complaint is unit not drying clothes. tested and verified complaint. tested air flow with unit and found poor air flow in unit. went to back of unit and found excess vent line. shortened the line up and checked for blockages. vent on the outside of the house is directly on the other side of the wall. went to vent outside and found vent completely blocked with lint. cleared blockage at the vent and unit passed the air flow test. unit is working as designed. job complete
We serviced a
WHIRLPOOL RANGE
Model WFG525S0JS2
Near Millsboro, DE 19966
Michael E.
Job Details: 07/20/2022
"CX complaint: dented control panel. Inspected and verified complaint. Documented dent in pics. New home that is not yet occupied. Replaced control panel, tested unit and it is now working properly. Job is complete"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS325FDAB06
Near Millsboro, DE 19966
Frederick R.
Job Details: 07/19/2022
CX complaint is no cool entire unit. Replaced Compressor and installed UV drier. Pressure tested unit with nitrogen at 140psi. While under pressure i checked all joints that were brazed as well as evaporator joints with Blu Monster and found no sign of leaks. Vac'd unit down to 30in for 15mins. Vac held after closing gauges. FIlled with 5.5oz of R134a. Once unit powered up i checked and saw full frost pattern forming on evap. Informed CX 24-48hrs for unit to get to temps before they begun using it. Unit is now working properly. Job is complete
Granholm’s
Millsboro, Delaware
08/02/2022
For the first time in a very long time we had wonderful customer service through a vendor. Not once but twice in ten days! Although we never wish for an appliance repair, we would happily reach out to you again with such great service.
Overall Experience
DCP
Millsboro, Delaware
06/29/2022
What a great Tech and experience!!
Overall Experience