Appliance Repair Lorton Virginia

VIA INC Rated 5.0 out of 5 stars based on 1 customer reviews

We serviced a
WHIRLPOOL WASHER
Model MVWX655DW1
Near Lorton, VA 22079
Tanner B.
Job Details: 07/21/2022
Loose connection on shifter. reseated and tested unit. job complete
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHZ00
Near Lorton, VA 22079
Robert W.
Job Details: 07/20/2022
"CX Complaint is the unit is making ice not dispensing water. Inspected unit and found unit is making ice just not dispensing water, Found valve is testing out of range replaced and tested unit is working properly."
We serviced a
MAYTAG WASHER
Model MVW6200KW0
Near Lorton, VA 22079
Demonte S.
Job Details: 07/20/2022
Inspected the unit. Found that the cx is saying that the Washer isn't fully Draining the clothes at the end of the cycle. Ran Service Diagnostics on the unit. Error Codes are Free = over sud error. Cleared error codes. Started a Normal cycle. Showed the cx that they are putting to much soap into the unit because no soap was added and there are still suds. Cx is using Pods. Advised that the cx switched to liquid. Unit is working as Designed.
We serviced a
MAYTAG DRYER
Model MED6200KW
Near Lorton, VA 22079
Demonte S.
Job Details: 07/20/2022
Inspected the unit. Found that the cx is saying that the Dryer is making a rattle noise / buzzing noise. I then checked the Motor Section. Tested the unit. Buzzing / Rattle Noise is coming from the Motor. Installed the Motor & Blower Wheel. Tested the unit. No Noise. Unit is working as Designed. ( Cx must fix the crimp vent issue. I think it's make the Motor over heat at time because air can't be removed properly.) (Any questions please check Sd Pictures.)
We serviced a
JENN-AIR REFRIGERATOR
Model JS48NXFXDE01
Near Lorton, VA 22079
Jason A.
Job Details: 07/18/2022
"CX complaint FRIDGE RC temps too cold - ice tea in door frozen. LED lighting not working. Found all lights in FC & RC not working, Unit was installed less than 30days.Test several from both compartments with LED tester. Check door switches & power to 120VAC & out of LED Aurora power supply. As soon as I made contact with J1 connector the lights all started working. Test door switches over 30X = OK. Measured RC cavity & pantry thermisters in icewater good. Cycled cavity 12 & pantry 4 air damper baffle. Set RC temp from 36 to 39 & CX will monitor RC items for freezing next 2 weeks & report to returning tech > JJ; ordrng 12 W11484836 (LEDs)s and 1 JJTORETURN (JJ TO RETURN)"
John
Lorton, Virginia
07/29/2022
Robert was kind, professional, and pleasant to work with.
Overall Experience