We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHZ04
Near Glenn Dale, MD 20769
Israel R.
Job Details: 07/20/2022
Customer complaint unit is freezing food in the refrigerator. I tested the unit temps and the unit is reading lowest 35. and freezer is about 5 degrees. The customer stated that the there is frost on the vent sometimes. I tested diffuser and the door is stuggling to close and open. IS does not sounds smooth and is rattleing. Ordering diffuser. Call customer when part is available.; ordrng 1 W11236851 (diffuser)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHM08
Near Glenn Dale, MD 20769
Israel R.
Job Details: 07/20/2022
SR// 7734158303. Customer complaint unit is overfrosting. I tested the unit and found the unit is full of ice. IUS a block of ice. I thawed everything. When i tested the thermistor under ce is reading 22k under ice about 8k. When put back together and tested at the control i get 8.5 after frost has been develpo in the tube. Called techline and they said that the thermistor is out of range that it needs to be exactly 8.7 ohms iunder ice and anything else is bad. Techline adviced to get the thermistor from whirlpool directly. Ordering thermistor.; ordrng 1 WPW10384183 (thermistor)
We serviced a
WHIRLPOOL FREEZER
Model WRF535SWHZ00
Near Glenn Dale, MD 20769
Mitchell H.
Job Details: 07/15/2022
cx complaint unit is now not stopping making ice and still leaking onto freezer floor. took everything out of freezer and took back panel off and found ball of ice on evap lines and partial frost pattern. informed cx this determines a low charge and a SS leak. alos cleared drain of ice in drain tube from freezer so that is good now. quoted her for SS repair and cx wants to think on it and will let us know. completing ticket
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT311FZDB02
Near Glenn Dale, MD 20769
Mitchell H.
Job Details: 07/15/2022
cx complaint units not sealing well and moisture in fridge. inspectd unit and confrimed both. the unit was very unlevel and leaning forward bad. adjusted feet all the way up and fixed door issue and now feels tighter and not so easily opened. as far as moisture this unit is in a garage and its about 95-100 in here right now and its only 80 degrees outside. unit is not in proper location requirements and will cotinue this issue until unit is in 60-90 degree room. informed cx that gladiator is made for the garage and to see if they can exchange for one if possible. otherwise unit is working as desinged.
We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Glenn Dale, MD 20769
Dustin F.
Job Details: 07/12/2022
"CX complaint: washer keeps throwing F2E2After initially inspectijng unit, i susspected a voltage drop in the wall, ( reading 10v i took a pic) after resecuring my leads i got a full 120.4-120.9v. i then checked DC voltage comming from the board to the UI and got 12.64 DC. Replaced the Ui board and tested unit. unit works as intended. CX is getting her servicer to double check the outlet tomorrow Just in case. Job Complete"