Appliance Repair Gettysburg Pennsylvania

VIA INC Rated out of 5 stars based on 0 customer reviews

We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF757SDHZ03
Near Gettysburg, PA 17325
Andrew S.
Job Details: 07/20/2022
Cx complaint is that when you open the doors and shut them again the unit is making a wierd noise. Upon arrival the cx was able to duplicate the noise. I found that the noise was the evap fan ramping up speed. I informed the cx that the noise was normal operation. Cx also stated that the unit had some moisture on the door seals and in the RC. I found that the RH door seal was not seated against the cabinet securely. I was able to reshape the gasket and it is now sealing correctly. Job complete.
We serviced a
KITCHENAID DISHWASHER
Model KDTM404KPS0
Near Gettysburg, PA 17325
Andrew S.
Job Details: 07/20/2022
Per previous diag I was able to access and replace the sump and heating element. I then ran the diag test and found that the unit is functioning as intended without any leaks. Job complete
We serviced a
WHIRLPOOL RANGE
Model MES8800FZ2
Near Gettysburg, PA 17325
Drew B.
Job Details: 07/16/2022
replaced rails and now checks good full closure
We serviced a
WHIRLPOOL DRYER
Model WED8540FW1
Near Gettysburg, PA 17325
Andrew S.
Job Details: 07/15/2022
Cx complaint is that the unit is not heating. It is turning on and rotating. Upon arrival I found that the unit is stacked. I entered into diag mode and found that it had an F4E3 and an F4E4. I then verified that the incoming voltage was correct. I am ordering an element and TCO kit. I will also be ordering a 2 tech due to the unit being stack and a basement sump being on the left side limiting access. Please contact cx when the parts are avialable and the contract is approved to schedule a retrun visit.; ordrng 1 WP3387747 (Element) and 1 280148 (TCO kit) and 1 2tech (2 tech)
We serviced a
MAYTAG RANGE
Model MGR8800FZ2
Near Gettysburg, PA 17325
Bernard M.
Job Details: 07/14/2022
"Replaced all parts per previous tech, set preheat for 350, after temp reached, opened door to release heat after closing the unit came back on to reach desired temp. Unit checks good"