We serviced a
WHIRLPOOL WASHER
Model MVW4505MW1
Near Galivants Ferry, SC 29544
Paul F.
Job Details:
11/17/2023
Customer complaint is unit does not always start. Customer had a video of the unit with all the lights on and the door lock light on but you could open the lid. Ran diagnostics and found no error codes and test cycle check ok. Goind to order a new control.; ordrng 1 W11675701 (control) and 1 W11626074 (control)
We serviced a
WHIRLPOOL WASHER
Model WRS321SDHZ08
Near Galivants Ferry, SC 29544
Jason T.
Job Details:
10/02/2023
"Cx complaint, slow ice production, tested all circuits...found icemaker harness backed out at the cabinet liner, repaired the loose connection and verified 121 vac at the ice maker harness. Ran factory diagnostics to verify all unit functions, also tested icemaker fill-harvest...working as designed.,."
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT314TFDW03
Near Galivants Ferry, SC 29544
Jason T.
Job Details:
09/14/2023
"Cx complaint, moisture collecting in the fridge on the shelves and the door seal, found several air gaps in the door seal and hinges allowing warm air to migrate into the fridge causing the moisture. Removed the doors and installed qty 5 washers to shim align the hinges-door to the cabinet, used a heat gun to seal the gaskets to the casing, verfiied all unit functions for proper operation...working as designed. Cx does not use Email.; ordrng 5 WP487576 (washer JT VS)s, used 5 WP487576 (WASHER) from stock"
We serviced a
MAYTAG DRYER
Model MEDC465HW0
Near Galivants Ferry, SC 29544
Jason T.
Job Details:
09/12/2023
"Cx complaint, long dry times any cycle, tested all circuits. Found motor harness connection backed out causing the 120 vac to the heater intermittent. Removed and repaired the harness connection, veriifed 120 vac at the heater circuit. Tested cycle temperature at 135 degrees, unit is working as designed."
We serviced a
WHIRLPOOL RANGE
Model WFG505M0BS3
Near Galivants Ferry, SC 29544
Jason T.
Job Details:
08/29/2023
"Cx complaint, surface temperatures very very hot to the touch, tested all surface temps, UI-Panel tested at 95 degrees, knobs 120 degrees, outer door glass 105 degrees, door handle 115 degrees. All surface temps tested within range, factory specs : Metal Knob and Handle 131°F (55°C) Plastic or plastic coated metal, Knob and Handle 167°F (75°C)Dial or Skirt of Knob +20° hotter than above figuresBare or painted metal 152°F (67°C) Porcelain enamel 160°F (71°C) Glass 172°F (78°C) Plastic 182°F (83°C) Tested all unit functions for proper operation...working as designed. Called tech line and spoke with Andrew to document findings."