We serviced a
KITCHENAID REFRIGERATOR
Model KRFC604FSS01
Near Delmar, DE 19940
Frederick R.
Job Details: 04/07/2023
Picked up both data loggers. Labeled in pics. CX stated that both units are now working good. Job is complete
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF767SDHZ03
Near Delmar, DE 19940
Michael E.
Job Details: 04/03/2023
"CX complaint: after previous SS service, unit works better but still to warm in FC. Tested and verified complaint. 15 degrees in FC and 37 degrees in RC. Unit is set at colodest setting for FC. Replaced evap harness. While i was replacing that i cvould hear the damper making rattling sound the whole time i was working in the FC. Confirmed it was the damper making that sound. Ordering damper control. Scheduled return visit for 4/7 any time.; ordering 1 WPW10479155 (control)"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC604FSS01
Near Delmar, DE 19940
Frederick R.
Job Details: 03/08/2023
Arrived at appt and opened control box and found the UI inside is not the proper one. Verified the right part ordered and labeled properly but packaged wrong. Installed IM and cleared frozen bin. Had another SS job at same CX and by the time I finished it had dropped 2 trays of ice (properly). Please have box checked by MR to verify proper UI before scheduling; ordrng 1 W11533213 (control kit (reorder)) and 1 look (loo
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRR56X18FW02
Near Delmar, DE 19940
Frederick R.
Job Details: 03/08/2023
"Replaced compressor, installed UV drier per prior diagmnosis. Pressure tested unit with 140psi of Nitrogen. Vac'e down to 30in for 15mins. Filled with 4.8oz or R134a. Final low side pressure was at 7psi. Compressor and all fans running properly. Informed CX 24-36 hrs for unit to get to temps. Job is complete"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC604FSS01
Near Delmar, DE 19940
Frederick R.
Job Details: 03/08/2023
Arrived at appt and opened control box and found the UI inside is not the proper one. Verified the right part ordered and labeled properly but packaged wrong. Installed IM and cleared frozen bin. Had another SS job at same CX and by the time I finished it had dropped 2 trays of ice (properly). Please have box checked by MR to verify proper UI before scheduling; ordrng 1 W11533213 (control kit (reorder)) and 1 look (loo