Important Service Call Pricing Update
Effective October 1, 2023
$139 for MD, VA, WVA, DE, PA, NC, SC
$175 + tax for Washington, DC
Appliance Repair Dayton Maryland
VIA INC Rated 5.0 out of 5 stars based on 2 customer reviews
We serviced a
JENNAIR RANGE
Model JDRP548HL01
Near Dayton, MD 21036
Robert L.
Job Details:
09/14/2023
"cx complaint right door not closing properly, found right hinge failed and damaged front panel fron inside, ordering hinges and front panel; ordrng 1 W11643630 (hinge left) and 1 W11643898 (hinge right) and 1 W11315557 (glass-door)"
We serviced a
JENN-AIR REFRIGERATOR
Model JBSFS48NMX00
Near Dayton, MD 21036
Robert L.
Job Details:
09/06/2023
"installed main control, unti went into defrost and heard water dripping into drain pan, cx had previously defrosted unit, found damper not aligned properly, reisntall damper, tested all ops ok"
We serviced a
JENN-AIR MICROWAVE
Model JMC2430LL00
Near Dayton, MD 21036
Robert L.
Job Details:
08/24/2023
"cx complaint random f1e6 has to reset breaker and random open close door issue, unable to enter service diag, found unit missing support rails, called techline since f1e6 generation error is new, they said after hard reset run one minute unit errors replace magnetron, they also said interlocks could cause false error and since rails missing most likely causing both issues"
We serviced a
JENN-AIR MICROWAVE
Model JMC2430LL00
Near Dayton, MD 21036
Robert L.
Job Details:
08/24/2023
"cx complaint random f1e6 has to reset breaker and random open close door issue, unable to enter service diag, found unit missing support rails, called techline since f1e6 generation error is new, they said after hard reset run one minute unit errors replace magnetron, they also said interlocks could cause false error and since rails missing most likely causing both issues, still waiting on whirlpool decision of who responsible for install correction, most likely ABW will return to complete proper installs"
We serviced a
JENN-AIR REFRIGERATOR
Model JBSFS48NMX00
Near Dayton, MD 21036
Dustin F.
Job Details:
08/22/2023
"ChrisContacted TL and spoke to chirs, he had me run test 89 for the heater and i was getting oF at control which indicates evap thermistor reading over 140 degrees which makes the unit unable to start a defrost cycle. checked thermistor and it was reading 68-70 degrees which is accurate. techline agrees unit needs new control.; ordrng 1 W11623098 (Control)"
Jamesy401
Dayton, Maryland

06/15/2023
Robert is incredible. He is a great diagnostician and shared all relevant information I feel that is required. He goes above and beyond to represent us with the vendor. I appreciate him and would definitely continue to use Via as a result of the relationship and rapport he has built with us.
Overall Experience





Dayton, Maryland

03/02/2023
Service tech was very kind and knowledgeable and did a great job 5⭐️
Overall Experience




