We serviced a
KITCHENAID REFRIGERATOR
Model KRFC704FPS00
Near Chevy Chase, MD 20815
Andrew H.
Job Details: 07/20/2022
"Customer complaint is units not cooling. I replace the compressor, condenser, dryer coupler. I pulled unit into a 30-in vacuum. And filled to 4.75 oz. Unit is now working properly."
We serviced a
WHIRLPOOL DISHWASHER
Model KUDS03CTSS3
Near Chevy Chase, MD 20815
Roberto I.
Job Details: 07/19/2022
"Cx complaint unit not draining properly, now stopped and clean light blinks.Found clean light blinking 7 times. Ran diag, the test cycle went all trough and the heater worked but the drain pump was noisy. Inspected control board, found sings of overheating around heater connection. Removed sump filter found area around chopper blade all clogged, removed debris, chopper blade ok Quoted repair $477.64 with $125 labor for drain pump WPW10348269 and control board WPW10084141 replacement. Cx declined. Collected $125; ordrng 1 WPW10348269 (drain pump) and 1 WPW10084141 (control board)"
We serviced a
JENN-AIR REFRIGERATOR
Model JFC2290VEM6
Near Chevy Chase, MD 20815
Roberto I.
Job Details: 07/19/2022
REmoved all the ice from freezer bottom and drip pan and replaced drain tube. Unit good to go.
We serviced a
KITCHENAID DISHWASHER
Model KDPM604KPS0
Near Chevy Chase, MD 20815
Roberto I.
Job Details: 07/18/2022
"CX complaint F8E4 message, unit is beeping.Ran test mode, confirmed and cloared F8E4. Inspected drip pan on the front, found water in it. Inspected unit inside, found a tall kitchen utensil blocking the middle spray arm and directing the water jet toward the door. Instructed cx. Removed water from drip pan and ran a cycle, the unit worked ok and didn't leak, the heater was already replaced during prev repair."
We serviced a
WHIRLPOOL DRYER
Model MGDX655DW2
Near Chevy Chase, MD 20815
Emmanuel R.
Job Details: 07/13/2022
"Cs unit is not drying clothes, I found the electrical connector to the heater element was not secure, not allowing heater to come on. Secured electrical connection and tested unit. Unit is now working as designed."