Appliance Repair Poolesville Maryland

VIA INC Rated out of 5 stars based on 0 customer reviews

We serviced a
KITCHENAID REFRIGERATOR
Model KRSC703HPS01
Near Poolesville, MD 20837
Justin S.
Job Details: 10/19/2022
the ujnit was still off when i arrived. flushed the system 3 times and replaced the valve and coupler. vacuummed the system down and filled to weight. ran test 4 and step 1 pressures equilized to 50psi quickly. step 4 low side pressure is 10psi and high side pressure is 150psi. step 5 low side pressure is 7psi and high side pressure is 165psi. the unit is cooling good. the unti si now good
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF560SEHZ00
Near Poolesville, MD 20837
Julian H.
Job Details: 07/13/2022
2YR WARRANTY COTSCO PURCHASEDCX complaint about light not working on FCand falling off position found that housing that holds light asm is deforming not staying in proper position causing to fall and affect light need all parts to attached light properly and prevent this to happened again; ordrng 1 WPW10313917 (housing)
We serviced a
MAYTAG WASHER
Model MVW7232HW0
Near Poolesville, MD 20837
Julian H.
Job Details: 07/08/2022
replaced ui documented all we have done so far with TL signal fail b4 Tech gave me file # documented thru svc matters as well stay with CX thru when unit is adding water to the cycle using extra power option found that it adds little bit of water then is suppossed to add some more during cycle extra power is to threat stains not to add more water then CX tested without powe option and unit brought enough water and kept on washing working as designed
We serviced a
JENN-AIR OVEN
Model JJW3430DS02
Near Poolesville, MD 20837
Julian H.
Job Details: 07/07/2022
replaced parts that JA send to CX control power board and console resume power and working
We serviced a
MAYTAG WASHER
Model MVWB865GW0
Near Poolesville, MD 20837
Julian H.
Job Details: 07/01/2022
CX complaint about unit not filling enough put unit on test cycle no errors did a calibration then went to the back and confirmed proper pressure from supply valve put uit on a normal cycle deep fill option and fwater got passed half of drum CX states it wasnt that way if CX calls back will need a control board; ordrng 1 W11162440 (cntrl-elec)