We serviced a
WHIRLPOOL RANGE
Model ACR2303MFW7
Near College Park, MD 20740
Andrew H.
Job Details: 07/21/2022
Customer complaint is the left front burner and left rear burner are not working inspected unit and found the bi-metal open on the bottom of the elements. Unit will need new elements and switches. Ordering parts. Please call with ETA on parts.; ordrng 2 W11396792 (Element)s and 2 W11396790 (Element)s and 2 814399 (Element harness)s and 2 WP3149400 (Infinite switch)s and 2 3148952 (Infinite switch)s
We serviced a
AMANA WASHER
Model NTW4516FW3
Near College Park, MD 20740
Andrew H.
Job Details: 07/18/2022
Customer complaint is the unit it is not dispensing cold water. Especially the internet sound long fill error code. I checked behind unit and found rubber hose to cold water pinched against the wall. I ran out of test cycle and found unit is now filming with water. I cleared area codes and it's now working properly
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT112CZJW00
Near College Park, MD 20740
Dustin F.
Job Details: 07/14/2022
"CX complaint: water leaking down into fridgeInspected unit, thawed out unit, verified unit Does indeed drain. Ohmed out Defrost heater. showed 106 ohms. wayyy out of range. ordering Evaporator assembly with defrost heater. please schedule as 2 count Sealed system tech job.; ordrng 1 W11368877 (EVap/defrost heater assembly) and 1 W11504449 (4/2-nr Al-00 (capillary To Evaporator)) and 1 W11225184 (200-mm- Al-00 (aluminum Suction Line To Evaporator))"
We serviced a
WHIRLPOOL WASHER
Model WFW3090JW0
Near College Park, MD 20740
Israel R.
Job Details: 07/07/2022
Installed all parts and tested. Unit is back to normal operations.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT138FZDW00
Near College Park, MD 20740
Mitchell H.
Job Details: 06/23/2022
cx complaint unti not cooling. got to unit and was off. turned it on and confirmed cmpressor runnig and fans on and running. opened system and found low charge. braised in a coupler and drier. vaccumed unit down to 30 in and held for 15 mins. didnt move from vaccum at all. filled unit to 4.15 oz and unit is now good to go