We serviced a
MAYTAG WASHER
Model MVWX655DW1
Near California, MD 20619
Robert A.
Job Details: 07/20/2022
I installed the ordered parts and tested the unit for the cx. The unit is working as designed.
We serviced a
MAYTAG O.T.R MICROWAVE
Model MMV4207JW0
Near California, MD 20619
Shane B.
Job Details: 07/19/2022
"cx complaint is the unit not heating and making a louder than normal buzzing noise. when i arrived it was unplugged. tested unit and confirmed complaint. unit makes a loud buzzing noise and does not heat at all. called techline, verified voltage to trans and tested diode. they advised replacing mag and diode together. SR#7734140863. documented with safety. they issued parts auth#M13K3K1WP1. ordering parts. quoted cx 120 for labor. she will pay on return but is going to call whirlpool and see if they will cover labor as well. cx asked that the unit be left down so its easier to install parts on return.; ordrng 1 W11391717 (mag) and 1 W11256462 (diode)"
We serviced a
MAYTAG WASHER
Model MVW6230HW2
Near California, MD 20619
Robert A.
Job Details: 07/14/2022
"Cx complaint that the unit is making weird noise and has a hard time spinning. I inspected the unit and confirmed the complaint. I found that the clutch's screw was loose not holding it in place. Which caused the belt to come off and damage the shield. I replaced the clutch and shield, the belt was not damaged. I calibrated and tested the unit for the cx. The unit is working as designed."
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX735SDHZ04
Near California, MD 20619
Robert A.
Job Details: 07/13/2022
Cx complaint that the unit's right RC door gasket is torn is not sealing well. I inspected the unit and confirmed the complaint. I noticed obvious tears on the inner part of the gasket that makes contact with the other door. Also the gasket is not flush against the cabinet. I replaced the gasket and used a heat gun to mold it as best as possible. The unit is now sealing and working as designed.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near California, MD 20619
Robert A.
Job Details: 07/12/2022
"Cx complaint that the unit is not cooling in the RC. I inspected the unit and confirmed the complaint. The RC temp is 51 degrees and FC is 3 degrees. I noticed ice on the evap wall. I removed the evap wall and the ice on the evap. I ran the defrost heater in test mode, the heater is working as designed. I found the thermistor directly on the evap coil rather than on the insulated portion of the coil. Techline instructed to have the thermistor on the insulated part of the evap to prevent it from shorting. I correctly positioned the thermistor and tested the unit for the cx. The unit is working as designed."