We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX735SDHZ07
Near Williamsburg, VA 23188
Lucas R.
Job Details:
12/01/2022
"cx complaint unit leaking, inspected all water lines, found no evidence of breaks in lines, found crack in drain pan, and calcium deposits in machine compartment, power cord crushed, and no water supply in store to test further.; ordrng 1 WPW10655368 (pan-drip) and 1 W11563716 (harness)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT519SZDM02
Near Washington, DC 20011
Mitchell H.
Job Details:
12/01/2022
cx complaint unit will cool fine for a few days then just thaw out and get warm for days. inspected unit and found freezer at 4 and fridge at 16. units cycling too lonog then going into defrost/idle for too long. unit needs control. cx paid service call and will let us know if they want to move forwards.
We serviced a
KITCHENAID REFRIGERATOR
Model KRFF507HPS00
Near Yorktown, VA 23692
Justin W.
Job Details:
12/01/2022
replaced fc led per service pointer tested unit working as designed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS325SDHB08
Near Centreville, VA 20120
Demonte S.
Job Details:
12/01/2022
"Installed the Harness Wire, Thermistor & Control Board. Tested the unit. Unit is starting to Cool. Unit is working as Designed."
We serviced a
WHIRLPOOL WASHER
Model WTW5057LW0
Near Catonsville, MD 21228
Robert L.
Job Details:
12/01/2022
"cx complaint noise and burner smell, found belt cover screw had fallen out and was rubbing cam pulley, removed old belf and cleaned cam and pulley installed new b elt, recalibrated and tested all ops ok, ordering new cover and screws; ordrng 1 W11409708 (belt shield) and 2 WP22001995 (screw)s"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC300ESS03
Near Glenelg, MD 21737
Robert L.
Job Details:
12/01/2022
"cx complaint leaking from hosuing , found slow leak from filter housing behind filter connectio, found corrosion once removed, replaced housing from pre-id, tested all ops ok, collected $309 visa cx paid in full......... while removing old housing i accidently broke tab to bracket (see pic), ordering bracket no charge; ordrng 1 WP67001668 (plate- filter) and 1 look (look)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX735SDHZ07
Near Norfolk, VA 23503
Carl A.
Job Details:
12/01/2022
"cx complaint of unit making loud noise when ice maker fills,checked unit unit to fin noise coming from water vavle when it fills the vavles is internaly failing ordering parts needed for repairs; ordrng 1 W11548540 ( ICEMAKER) and 1 W11548535 ( VALVE)"
We serviced a
WHIRLPOOL RANGE
Model KSDG950ESS1
Near Chestertown, MD 21620
Alexander W.
Job Details:
12/01/2022
"Installed part per previous diag tested unit, unit is now operating as designed job is complete cx paid remaining balance by CC"
We serviced a
MAYTAG DRYER
Model MEDB835DW4
Near Inwood, WV 25428
Ken M.
Job Details:
12/01/2022
"Customer complaint is that the unit is not drying properly, has to run multiple cycles to dry, and is running noisy. Unit tested and noise confirmed, but unit is heating. Inspection of the blower wheel found the wheel is intact. Noise is from the rear support rollers. Customer had a vent restriction which was resolved before I got here, but there was lint/hair backed up into the unit and vent. Vent and base cleared out and rollers replaced. Unit retested and running properly. Old parts left with customer.; ordrng 2 W10314173 (support)s, used 2 W10314173 (roller) from stock"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX986SIHV02
Near Chesapeake, VA 23322
Branden R.
Job Details:
12/01/2022
cx complaint aig con ci for same issue. im making noises checked unit found during test 3 evap fan in freezer makes a loud pulsating sound while testing disassembled and found bad evap motor order both evap motors and controls just in case .; ordrng 1 W11452196 (evap motor) and 1 WP67006337 (fan blade) and 1 W10843055 (control) and 1 W10830278 (control) and 1 W11087438 (fridge evap motor)
We serviced a
WHIRLPOOL WASHER
Model WTW5000DW3
Near Inwood, WV 25428
Ken M.
Job Details:
12/01/2022
"Customer complaint is that the unit is not agitating. Per SP W11531483B, inspected the actuator. Found the actuator arm disengaged from the splutch. Actuator replaced and unit tested. Unit is working properly. Old part left with customer."
We serviced a
WHIRLPOOL DISHWASHER
Model WDT970SAKZ0
Near Bridgeville, DE 19933
Frederick R.
Job Details:
12/01/2022
Replaced left mount assy and left adjuster per prior diagnosis. Unit is now repaired. Could not test unit because it was in garage. Job is complete
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX735SDHZ07
Near Norfolk, VA 23503
Carl A.
Job Details:
12/01/2022
"cx complaint of unit making loud noise when ice maker fills,checked unit unit to fin noise coming from water vavle when it fills the vavles is internaly failing ordering parts needed for repairs; ordrng 1 W11548540 ( ICEMAKER) and 1 W11548535 ( VALVE)"
We serviced a
WHIRLPOOL WASHER
Model MVW7232HW0
Near Ashburn, VA 20148
Ricky E.
Job Details:
12/01/2022
"installed part, unit xks ok.."
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF757SDHZ03
Near Potomac, MD 20854
Andrew H.
Job Details:
12/01/2022
"Cx complaint unit is not cooling. Found locked up compressor. Replaced compressor, coupler, drier. Pulled unit to 30 inch vacuum. Filled unit with 56g of R600a. Unit is now working properly."
We serviced a
MAYTAG WASHER
Model MVWC565FW2
Near Forest Hill, MD 21050
Neil H.
Job Details:
12/01/2022
REPLACED THE RUN CAP AND RECALB. WASHER UNIT CHECKED GOOD.
We serviced a
WHIRLPOOL DISHWASHER
Model WDF520PADM9
Near Silver Spring, MD 20906
Julian H.
Job Details:
12/01/2022
CX complaint about unit not washing put unit on test mode error F4E3 motor not running let auto testrun confirmed water on unit also motor receiving 120vac but not running need sump/motor scheduke with office for tomorrow; ordrng 1 W11025157 (pump&motor)
We serviced a
WHIRLPOOL DRYER
Model WED8127LW1
Near Conway, SC 29527
Jason T.
Job Details:
12/01/2022
"Installed UI-Panel, tested all unit functions for proper operation...working as designed."
We serviced a
WHIRLPOOL WASHER
Model MVWX655DW1
Near Glen Allen, VA 23059
Thomas B.
Job Details:
12/01/2022
Cx complaint unit is not working properly inspected unit found unit leaning to the right rear removed and replaced the suspension rods tested and inspected for proper use unit now functions normally charged 360.52 cx paid by CC.
We serviced a
WHIRLPOOL WASHER
Model WTW4816FW2
Near Colonial Heights, VA 23834
Chris B.
Job Details:
12/01/2022
cx comp unit will squeel really loud insp unit could not duplicated noie did find rubber on belt gaurd did replaced belt and splutch tested unit working as desighned if cx call back unit will need gear case
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRB533CZJZ00
Near Richmond, VA 23220
Joseph D.
Job Details:
12/01/2022
"did not have evaporator with me, replaced compressor and unit had full frost pattern, pullinbg .7 amps working properly."
We serviced a
WHIRLPOOL WASHER
Model MVWC565FW3
Near Dover, PA 17315
Sal R.
Job Details:
12/01/2022
CX complaint is that the unit is not completing a wash cycle. I found that the unti had aF8E1 error code. I foujhd the cold side is not opening. I attempted to inspect the valve and found that the supply valve should be replaced. I advised CX to have a licenased plumber inspect the valve and before next visit. I have set a retun date for 12/8; ordrng 1 W11038689 (Water inlet valve 55 @ tribs)
We serviced a
WHIRLPOOL WASHER
Model WFW6620HC0
Near Clinton, MD 20735
Robert A.
Job Details:
12/01/2022
Cx complaint that the unit is not starting. I inspected the unit to confirm the complaint. The start button is not responding at all. I entered test mode and it just continually flashes 'f6e2'. I cycled power and it did the same thing. I enter test mode and checked the interface test and most buttons did not respond. The unit needs a new control and UI panel. I quoted the cx for the repair and collected the service call by CC.; ordrng 1 W11324037 (control panel 163.35) and 1 W11322905 (control board 222.14)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRV976FDEM00
Near Richmond, VA 23233
Jerod R.
Job Details:
12/01/2022
"tested unit found evidence of leak at ff evap, compressor is short cycling, and control has no control on unit when unit is set to cooling off unit still runs"
We serviced a
WHIRLPOOL WASHER
Model WTW5105HW2
Near Rockville, MD 20853
Julian H.
Job Details:
12/01/2022
CX complaint about unit not sounding confirmed issue went to test mode no errors reset power for 1 min same result issue with speaker on ui replaced ui from preid unit is back to normal working fine
We serviced a
KITCHENAID REFRIGERATOR
Model KFIS29PBMS02
Near Clifton, VA 20124
Demonte S.
Job Details:
12/01/2022
"Inspected the unit. Found that the cx is saying that the Freezer isn't getting cold enough. Checked the Freezer Evaporator Section. Found a ball of Ice on the Cap / Suction line only at the Freezer. Unit will need a seal System Repair. Cx paid for the Service Call Only by Check. Check is in the Blue money bag. If the cx calls back order the Compressor = W10276644, Drier = Wpw10143759, Coupler = W11506635 , Evaporator Freezer = WPW10608485 & Refrigerator Evaporator = W11492867. Don't go without parts. This will need to be counted as a 4 Count Seal System Repair."
We serviced a
KITCHENAID REFRIGERATOR
Model KRSF705HPS04
Near Bethesda, MD 20815
Samuel R.
Job Details:
12/01/2022
cx complaint unit is not dispensing water.inspected unit and could confirm cx complaint.tested unit with no filter and still got no water.ran service test 46 and got no water.checked door harness for unit and narness is good.checked water valve and found dual valve to be bad.will also replace inlet valve aswell its humming loud to but letting water through.unit will need both water valve W11512399 2 tribles WPW10341320 36 tribles ; ordrng 1 WPW10341320 (dual valve) and 1 W11512399 (inlet valve)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS311SDHM08
Near Silver Spring, MD 20906
Andrew H.
Job Details:
12/01/2022
"Cx complaint unit is not making ice. Inspected FC, measured cabinet temp at 0 degrees F, forced harvest cycle, ice maker dumped full tray with full size cubes, noticed poor water flow from fill tube at beginning of cycle, checked water dispenser, also exhibiting poor flow. Checked water line, line is connected with piercing valve, this is likely cause of poor flow. Based on full tray upon arrival, determined issues are caused by bad ice maker. Ordering ice maker (W11546935), scheduled return job for Monday 12/12/22; ordrng 1 W11546935 (Ice maker)"
We serviced a
WHIRLPOOL RANGE
Model WFG505M0BS4
Near Conway, SC 29526
Jason T.
Job Details:
12/01/2022
"Installed oven door gasket, verified all unit functions for proper operation...working as designed."
We serviced a
MAYTAG WASHER
Model MVWB765FW3
Near Spotsylvania Courthouse, VA 22551
Eric F.
Job Details:
12/01/2022
"sr# 7735178788Confirmed cx complaint unit not starting cycle. Found 'start/pause' button on UI not functioning properly, will not register when you hould your finger down to 'start' cycle, just beeps over and over. Replaced with pre-id'd part, issue persists. Unit functions when tested in diagnostic mode but something in the control is prohibiting the UI from registering that your finger is being 'held' down instead of tapping it. Techline advised ordering control and confirming lid lock function on return with new control. Ordering control.; ordrng 1 W11429620 (control)"
We serviced a
KITCHENAID REFRIGERATOR
Model KSSC36QMS02
Near Midlothian, VA 23113
Jerod R.
Job Details:
12/01/2022
"tested unit unti has bad controls , tested unit power being cut and returns every 20 sec , ordered new control; ordrng 1 W10818296 (cntrl-elec) and 1 WP2259350 (cntrl-elec)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS321SDHW01
Near Montclair, VA 22025
Carl R.
Job Details:
12/01/2022
"Cx complaint is, ICE MAKER IS NOT WORKING. Checked unit and seen ice was in the ice maker molding. Ice never fully formed for ice maker to put ice in the bin. Ice maker ice is working properly, and the freezer is not reaching prowr temperature. Cx has digital thermometer reading 28 degrees. I used my thermocouple and got 32 in the refrigerator. Talked to DS about the situation. He recommended drain and fill. Coupler and drier. Ordering coupler876764, drierWPW10143759; ordrng 1 876764 (Coupler) and 1 WPW10143759 (Drier)"
We serviced a
WHIRLPOOL RANGE
Model WFE535S0LS0
Near Virginia Beach, VA 23464
Zachery R.
Job Details:
12/01/2022
"replaced switch and burner, tested, unit working as designed."
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF555SDFZ15
Near Silver Spring, MD 20906
Andrew H.
Job Details:
12/01/2022
"Cx complaint unit is not dispensing water. Tested dipenser, no water came out, ice maker is making ice. Pulled out unit, inspected water line, found no kinks or blockages, opened RC and removed cover, inspected valve, disconnected water dispenser line, no water leaked from dispenser, actived valve, valve delivering water. Removed dispenser line, found ice causing blockage. Melted ice to clear blockage. Re-assembled unit. Noticed void in door liner, as a precaution installed, shim on door. Unit is now working properly."
We serviced a
WHIRLPOOL MICROWAVE
Model WML55011HS4
Near Lusby, MD 20657
David J.
Job Details:
12/01/2022
Complaint unit will not continue to heat. After previous tech visit they had stated to replace fan board. Installed new board and found was still not working. Inspected harness and found it was not seated all the way on connector of main board. Fan is now working but unit doesnt continue to heat after 15 seconds. Found cooling fan to not move either. After seating harness it now works. Called Techline and waited on hold for 30 minutes SR#7735177156. Came to conclusion after testing voltage at P4-1 to ground and had 119vac. Tested voltage at transformer during heat cycle and had 122vac. Found two wires on harness not connected to control all the way. Unit needs new transformer. Ordering for return visit. ; ordrng 1 W11628655 (Transformer)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT518SZFM02
Near Kensington, MD 20895
Andrew H.
Job Details:
12/01/2022
"Cx complaint is unit still has frost build up on top middle of door and top front middle of freezer cabinet after door replacement. Called WP TL, after speaking with representative and sending detailed photos of unit, representative recommeded another door replacement. Representative stated if third door does not reconcile issues, unit will need to be replaced. Inspected new freezer door, discovered plastic washer/spacer on bottom of hinge was no longer present, causing metal to metal contact between freezer door and bottom hinge. Installed new washer from loose spares in van. FC door (W10803965) is temporarily out of stock, will contact cx to schedule replacement when door is available.7734376151; ordrng 1 W10803965 (FC door)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS325SDHB08
Near Powhatan, VA 23139
Jerod R.
Job Details:
12/01/2022
"replaced ordered parts and tested unit condenser fan started as normal , unit is now fully functional"
We serviced a
KITCHENAID OVEN
Model KEBK171BSS00
Near Rockville, MD 20850
Julian H.
Job Details:
12/01/2022
CX complaint about nothing working after power outage remove console confirmed control thermal fuse open replaced with preid & working
We serviced a
WHIRLPOOL WASHER
Model WFW6620HC2
Near Virginia Beach, VA 23452
Austin D.
Job Details:
12/01/2022
cx complaint the unit is not draining. checked the unit and ofund a c logged drain filter. removed all debri and tested operation. unit is running as designed. no error showed after clearing drain.
We serviced a
KITCHENAID ICE MAKER
Model Kuis18nnts3
Near Huntingtown, MD 20639
David J.
Job Details:
12/01/2022
"CX complaint after performing clean cycle unit stopped working correctly. Arrived today and unit was powered on. There was ice on the plate but small ships of ice and water in the ice bin. Circulation pump was working correctly and running water over the plate, but could not get the drain pump to drain water out of bin tried forcing a drain but would not work. Unit needs both Yvette thermistor and Ben thermistor as well as a drain pump. Quoted CX for repair and he will let us know within 30 days. CX paid 120 for service call.; ordrng 1 W11566407 (Res drain pump)"
We serviced a
MAYTAG REFRIGERATOR
Model MSS25N4MKZ04
Near Abbottstown, PA 17301
Sal R.
Job Details:
12/01/2022
"CX complaint in that unit is freezing food in the RC. I found that the evap coil has low to no frost pattern and that the Compressor is pulling less then 0.05 AMP's . Unit will need a sealed system reapir. I am ordering 1 compressor , 1 evap , 1 drier filter , and accoupling couplings for R600A unit. raturn has been set for 12/8 and will need to be 3 call counted due to sealed system and LOKRING required.; ordrng 1 W11580057 (compressor 16 @ tribs) and 1 W11504415 (coupling) and 1 W11504431 (coupling 56 @ tribs) and 1 W11506619 (coupling 31 @ tribs) and 1 W11546692 (evap coil 4 @ tribs) and 1 W11504449 (coupling 31@ tribs) and 1 W11506619 (coulping 31 @ tribs) and 1 W11109499 (filter drier 100 @ tribs) and 1 W11504433 (coulping 15@ tribs) and 1 W11504447 (coupling 36@ tribs) and 1 LOKRING (LOKRING) and 1 3callcount (3 call count) and 1 LOOK (LOOK)"
We serviced a
KITCHENAID DISHWASHER
Model KDTM604KPS0
Near Richmond, VA 23233
Jerod R.
Job Details:
12/01/2022
"tested unit foun unit had f7-e1 twice and f9-e1, unit also falls under the sp S17304, ordered needed parts to correct issue, unit was under warranty at time of sch. due to costco 2 year warranty; ordrng 1 W11416362 (sump)"
We serviced a
KITCHENAID REFRIGERATOR
Model KSSC36QMS02
Near Midlothian, VA 23113
Jerod R.
Job Details:
12/01/2022
"tested unit unti has bad controls , tested unit power being cut and returns every 20 sec , ordered new control; ordrng 1 W10818296 (cntrl-elec) and 1 WP2259350 (cntrl-elec)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Sterling, VA 20164
Jason A.
Job Details:
12/01/2022
CX complaint FRIDGE doesnt dispense water. Found tank has a cut. See SDpics. RC door switch sticks. Parts in stock > JJ; ordrng 1 W11384469 (RC door sw item4) and 1 W11566768 (reservoir)
We serviced a
KITCHENAID MICROWAVE
Model KMBP100ESS
Near Chesapeake, VA 23322
Zachery R.
Job Details:
12/01/2022
"assisted bx with repair. tested, unit working as designed."
We serviced a
WHIRLPOOL WASHER
Model WTW4955HW3
Near Gaithersburg, MD 20886
Ricardo S.
Job Details:
12/01/2022
Replaced cntrl board.. unit tested . normal cycle working ok
We serviced a
JENN-AIR REFRIGERATOR
Model JF42NXFXDE02
Near Great Falls, VA 22066
Jason A.
Job Details:
12/01/2022
B.I. FRIDGE. Replaced all 12 LEDs W11632139 per TSP #: W11606409 Rev E / / / S84638. Test all leds are working > JJ
We serviced a
WHIRLPOOL RANGE
Model WEE730H0DS0
Near Bear, DE 19701
Michael E.
Job Details:
12/01/2022
"CX complaint: F8E0 error code. Tested and verified complaint. Cooling fan at 104.8 olms. 5vdc from control to hall sensor. Control board has been replaced twice to address this same issue. Ordering cooling fan assembly. CX paid for service, part, S&H. CX will owe 110.00 for labor upon return visit. Cannot reschedule due to NW part; ordrng 1 W11107275 (fan-blwr)"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFF707ESS01
Near Silver Spring, MD 20906
Julian H.
Job Details:
12/01/2022
CX complaint about unit having an issue with dispenser when trying to get ice will get water thru dispenser only happens randomly was able to confirmed issue tested pads on test 9 responding to test remove ui & confirmed connections siting all the way tight problem with ui & pads also CX states that water pressure is low confirmed took filter out 7 pressure is back ordering filter head CX will have a filter by the time we replace parts; ordrng 1 W11089931 (ui) and 2 WPW10346924 (pad)s and 1 W11194438 (housing)
We serviced a
WHIRLPOOL RANGE
Model KSDG950ESS1
Near Alexandria, VA 22305
Eric W.
Job Details:
12/01/2022
cx complant of the console is not working properly buttons not working installed new console and tested unit unit is now working properly
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHZ04
Near Bunker Hill, WV 25413
Ken M.
Job Details:
12/01/2022
Door replaced. Top of the door sticks out further than the bottom. Heat applied to the gasket with the door held closed to help pull the door in. Unit is working properly. Old part left with customer.
We serviced a
MAYTAG WASHER
Model MVW7230HW0
Near Raccoon Ford, VA 22701
Robert W.
Job Details:
12/01/2022
"CX Complaint is the unit is making noise during agitation cycle. Inspected unti and found unit is making noise on back spin during agitation, Called techline SR#7735177359 techline said to check rotor and slide make sure everything is seatted properly. The rotor screw will not come off gearcase broke two bits trying to remove screw. unit will need gearcase, rotor, stator, clutch and screws; ordrng 1 W11449841 (Gearcase) and 1 W11195971 (Stator) and 1 W10754448 (Clutch) and 6 W11027980 (Screws)s and 1 W10734521 (Slider) and 1 W11260238 (Rotor) and 1 Look (Look)"
We serviced a
KITCHENAID DISHWASHER
Model KDTM604KPS0
Near Richmond, VA 23233
Jerod R.
Job Details:
12/01/2022
"tested unit foun unit had f7-e1 twice and f9-e1, unit also falls under the sp S17304, ordered needed parts to correct issue, unit was under warranty at time of sch. due to costco 2 year warranty; ordrng 1 W11416362 (sump)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHV04
Near Richmond, VA 23221
Joseph D.
Job Details:
12/01/2022
"cx complant unit clicking when opening dsoor confirmed complaint. adjusted ff door to proper height and it no longer clicks, adjusted freezer gasket, and calibrated measured fill to dispense 18 ounces instead of 8 at customers request"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT138FFDM01
Near Germantown, MD 20874
Andrew H.
Job Details:
12/01/2022
"cx complaint is the unit is locked up. i replaced compressor, coupler and drier. pulled unit into a vac and filled to 47g. unit is now working properly"
We serviced a
KITCHENAID DISHWASHER
Model KDPM604KPS1
Near Midlothian, VA 23112
John P.
Job Details:
12/01/2022
"CX complaint unit not working checked unit found bad wash motor.F9e1 f7e1, ; ordrng 1 W11416362 (Sump)"
We serviced a
KITCHENAID REFRIGERATOR
Model KSSO48QMB01
Near Edgewater, MD 21037
Shane B.
Job Details:
12/01/2022
cx complaint is the unit not cooling. cx said another company worked on unit and said it has a SS leak. when i arrived unit was running. temp in FC was 41. compressor is running but buzzing a lot and is very hot. condensor fan is not running. compressor pulling 1.2amps. condensor fan only gettingn 7vac. control board in top of unti is beeping. 2 short beeps then a puase then it repeats. evap has only a small amount of frost at top. evap fan is not running. it turns half a rotation then stops then moves a little bit again. with evap fan unplugged condensor fan starts running. i called techline they advised replacing evap fan and control board with kit from service pointer. SR#7735172247. cx paid in full for repair. schedule when parts are avaiable. techline advised leaving unit powered off.; ordrng 1 W10818296 (control kit) and 1 W10822580 (evap fan motor)
We serviced a
KITCHENAID DISHWASHER
Model KDTM404KPS0
Near Herndon, VA 20171
Richard B.
Job Details:
12/01/2022
"CX got notified about a issue. Found unit needs heater replaced due to brass grommetts , Tried several times to remove , A loose board in the back is holding machine from coming out, Advised CX to call installers that installed to have removed then call us back. Part is on site , Further work needed, CX will call via, RB; saved tckt"
We serviced a
WHIRLPOOL DISHWASHER
Model WDT970SAKZ0
Near Richmond, VA 23233
Jerod R.
Job Details:
12/01/2022
new tub was twisted reoreded; ordrng 1 w11409866 (tub)
We serviced a
WHIRLPOOL OVEN
Model WEG515S0FS2
Near Chesterfield, VA 23832
John P.
Job Details:
12/01/2022
CX complaint that center of oven doesn't cook evenly that the outer edges of food she is cooking will over cook edges before middle is done.342356340368337368Average 351 advised CX unit is heating as designed.
We serviced a
WHIRLPOOL OVEN
Model WEG515S0FS2
Near Chesterfield, VA 23832
John P.
Job Details:
12/01/2022
CX complaint that center of oven doesn't cook evenly that the outer edges of food she is cooking will over cook edges before middle is done.342356340368337368Average 351 advised CX unit is heating as designed.
We serviced a
KITCHENAID REFRIGERATOR
Model KBSD608EBS01
Near Gaithersburg, MD 20882
Ricardo S.
Job Details:
12/01/2022
"Replaced LEd kit, all lights working ok"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF555SDFZ15
Near Dale City, VA 22193
Demonte S.
Job Details:
12/01/2022
Installed Ice Maker. Tested the unit. Unit Filled and Harvested. Unit is working as Designed.
We serviced a
MAYTAG WASHER
Model MVW6230HW2
Near Winchester, VA 22602
Ezra M.
Job Details:
12/01/2022
"f9e1 error. used manual activation to turn on drain pump, no noise from pump. pulled up on wire harness, drain pump started running, and stopped when I let go. verified good connection at drain pump, ordering lower wire harness due to short in line.; ordrng 1 W11590868 (lower wire harness)"
We serviced a
AMANA WASHER
Model NTW4516FW3
Near Aberdeen, MD 21001
Neil H.
Job Details:
12/01/2022
"CX COMPLAINT THE WASHER TEARING CLOTHES SEEN BASKET RUSTING AND ROUGH SPOTS ON SPIN BASKET; ordrng 1 W10554251 (spin basket) and 1 WP21366 (nut-spaner) and 1 WP389140 (Whirlpool Washer Drive Block) and 1 285565 (agitator assy,comp)"
We serviced a
WHIRLPOOL DRYER
Model WED5620HW2
Near Hyattsville, MD 20785
Shane B.
Job Details:
12/01/2022
replaced blower wheel and tested unit for cx. unit is working as designed.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS325SDHZ08
Near Chesapeake Beach, MD 20732
David J.
Job Details:
12/01/2022
CX complaint unit is not dispensing water arrive to unit and customer showed that waterline had a kink in the hose. Remove back panel and straighten waterline and removed. Kink placing it back tested water and still had no water coming out. Went under sink and found waterline was turned off turned waterline on attempted to dispense water. Water is now coming out Ran about 6 cups of water. No more air in the line. Unit is now working as designed job complete
We serviced a
KITCHENAID REFRIGERATOR
Model KRMF706ESS01
Near Alexandria, VA 22312
Eric W.
Job Details:
12/01/2022
"cx complaint was fruit/meat storage freezing up- ice build up causing issues, like no ice-not cooling comfirm complaint seen ice on the ice box adaper which in melting and causing water to build up under crisper drawer unit needs new adaptor and gaskets; ordrng 1 WPW10320706 (gasket) and 1 WPW10280988 (gasket) and 1 W11126056 (adaper)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHZ00
Near Frederick, MD 21703
Ricardo S.
Job Details:
12/01/2022
Replaced freezer door.. unit tested and dispenser working ok
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS555SIHZ06
Near Alexandria, VA 22315
Lloyd B.
Job Details:
12/01/2022
Cx complained the unit did not dispense ice. Inspected the unit and found the auger motor coupler teeth are broken. Unit needs new auger motor coupler; ordrng 1 WP2220458 (auger motor coupler)
We serviced a
KITCHENAID DISHWASHER
Model KDTE234GPS1
Near Sterling, VA 20165
Jason A.
Job Details:
12/01/2022
CX complaint DW leaks. Found leak water dripping at coupler of supply line. See SDpics. Tightened fitting & watched for drips > JJ
We serviced a
KITCHENAID DISHWASHER
Model KDTE104KPS1
Near Gaithersburg, MD 20879
Julian H.
Job Details:
12/01/2022
replaced sump couldnt tested unit was uninstalled
We serviced a
WHIRLPOOL FREEZER
Model WZF34X18DW06
Near Chester, VA 23831
John P.
Job Details:
12/01/2022
Installed compressor and control tested working as designed.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT314TFDW03
Near Winchester, VA 22602
Ezra M.
Job Details:
12/01/2022
installed evap fan motor and harness. unit working properly; saved tckt
We serviced a
WHIRLPOOL REFRIGERATOR
Model KRFF507HPS02
Near Virginia Beach, VA 23456
Austin D.
Job Details:
12/01/2022
"sr 7735172525 cx complaint the ice is forming underneath the bin. checked the seals and all seals seem to be good to go. water must be coming from the ice maker section since where the water is located. therefore, ordering a new ice maker and water valve to resovle the issue. will return once the parts come in. if issue persists after this repair techline says we will need to replace the fridge left door.; ordrng 1 W11482383 (dual valve) and 1 W11087201 (heater) and 1 WPW10553630 (heater cover) and 1 W11579560 (ice maker)"
We serviced a
WHIRLPOOL REFRIGERATOR
Model KRFC604FSS02
Near Kensington, MD 20895
Roberto I.
Job Details:
12/01/2022
"CX complaint icemaker rarely makes ice.Ran test 120, the icemaker cycled very noisy and got stuck on 02. Removed part, found it broken. Fill tube heater ok. Ordering icemaker W11557000. Cx paid in full ($406.28 with check # 4661); ordrng 1 W11557000 (icemaker)"
We serviced a
JENN-AIR REFRIGERATOR
Model JFFCC72EHL02
Near Arlington, VA 22201
Emmanuel R.
Job Details:
12/01/2022
"Cs water filter wont come out, confirmed complaint. I found the water pressure was holding filter in place but once got it out it worked fine. Customer didnt want to replace the filter head since this one isnt leaking or broken. Installed new water filter and had the customer take it out and reinsert it so she can have a feel for it. Collected for svc call."
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF767SDEM01
Near Newark, DE 19713
Andrew W.
Job Details:
12/01/2022
"Cx complaint is unit has ice build up in freezer. inspected and verified complaint. found drain tube clogged. cleared drain tube, removed ice, and tightened fc door handle. unit is working as designed. job complete"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRX735SDHZ04
Near Portsmouth, VA 23707
Zachery R.
Job Details:
12/01/2022
"cx complaint no ice, checked unit, come to find defective filter cover, tested icemaker, icemaker is working as designed. ordering filter cover to complete repair.; ordrng 1 WP67006331 (cover-filt)"
We serviced a
KITCHENAID REFRIGERATOR
Model KRFC704FPS04
Near West Springfield, VA 22152
Carl R.
Job Details:
12/01/2022
"Cx complaint is Broken or Missing Parts - FDBM - PRE-ID Door Dented/Scratched. Removed door from box and held the door against the old door, new door matches perfectly against the frame and handle aligned perfectly. Put new door and handle on freezer rails and heat treatment to door gasket. Unit working properly."
We serviced a
KITCHENAID DISHWASHER
Model KDPM604KPS0
Near Wellsville, PA 17365
Sal R.
Job Details:
12/01/2022
"I was able to uninstall the unit and replaced the harness. I then tested and found the same results. I reented Diag and found errors to include F10E2 and F10E3. I ran the unit with the vent fan connected and found the disruption at the UI causing the unit to malfuntion. I canceled the cycle and disconnected the vent fan motor. I then ran the unit and found it to be opperating as designed. I called Whirlpool and explained my finds. I am ordering 1 vent fan motor (W11414073) . Once the part is avalible, please ahve somone form the office call ot set a retun date. Please see SR # 7735122651.; ordrng 1 W11414073 (vent fan motor) and 1 LOOK (LOOK)"
We serviced a
KITCHENAID MICROWAVE
Model KMBP100ESS20
Near Ashburn, VA 20148
Ricky E.
Job Details:
12/01/2022
"customer stated that the unit element clop was broken. verified issue and replaced the klip, unit ckso9k.."
We serviced a
WHIRLPOOL DISHWASHER
Model WDT750SAKZ0
Near Virginia Beach, VA 23464
Zachery R.
Job Details:
12/01/2022
"replaced heater, tested, unit working as designed."
We serviced a
KITCHENAID REFRIGERATOR
Model KRMF706EBS01
Near Falls Church, VA 22042
Christian C.
Job Details:
12/01/2022
"Cx complaint of a clicking behind unit and unit is not cooling. Inspected unit had been unplugged since for a week. After plugging back in unit 3 way valve just constantly clicks and compressor does not kick on. Ran test 5 and compressor at max speed unit is pulling 1.85 amps. Ran test 4 and went through no issues. Called techline. Advised to replace pantry ui, pantry harness, and ice box fan. Quoted cx and they will not be going through with repair. Cx paid for service call."
We serviced a
WHIRLPOOL DISHWASHER
Model MDB8959SKZ0
Near Crofton, MD 21114
Dustin F.
Job Details:
12/01/2022
"CX complaint: Middle Rack was broke and couldnt go back inInspected unit, found the adjuster had come loose off the rack, Readjusted the adjuster since there was no damage. tested unit, unit working as intended.; ordrng 1 Look (Look)"
We serviced a
WHIRLPOOL WASHER
Model WTW4816FW3
Near Alexandria, VA 22303
Lloyd B.
Job Details:
12/01/2022
"Cx complained the unit did not operate correctly. Installed new control and after calibration, tested in diagnostics and it now operates as designed. Job complete"
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF757SDHZ03
Near Spotsylvania Courthouse, VA 22551
Eric F.
Job Details:
12/01/2022
"Confirmed cx complaint unit making excess vibrating noise, door handles loose. Tightened handles. Found condensor fan vibrating due to unit not being properly level. Leveled unit, tested unit, unit working as designed."
We serviced a
MAYTAG REFRIGERATOR
Model MSS25N4MKZ04
Near Abbottstown, PA 17301
Sal R.
Job Details:
12/01/2022
"CX complaint in that unit is freezing food in the RC. I found that the evap coil has low to no frost pattern and that the Compressor is pulling less then 0.05 AMP's . Unit will need a sealed system reapir. I am ordering 1 compressor , 1 evap , 1 drier filter , and accoupling couplings for R600A unit. raturn has been set for 12/8 and will need to be 3 call counted due to sealed system and LOKRING required.; ordrng 1 W11580057 (compressor 16 @ tribs) and 1 W11504415 (coupling) and 1 W11504431 (coupling 56 @ tribs) and 1 W11506619 (coupling 31 @ tribs) and 1 W11546692 (evap coil 4 @ tribs) and 1 W11504449 (coupling 31@ tribs) and 1 W11506619 (coulping 31 @ tribs) and 1 W11109499 (filter drier 100 @ tribs) and 1 W11504433 (coulping 15@ tribs) and 1 W11504447 (coupling 36@ tribs) and 1 LOKRING (LOKRING) and 1 3callcount (3 call count) and 1 LOOK (LOOK)"
We serviced a
MAYTAG DRYER
Model MED7230HW2
Near Elkton, MD 21921
Alexander W.
Job Details:
12/01/2022
Cx stated strange noise coming from dryer inspected tested and verified cx complaint found back left drum support defective ordering two drum supports just in case. Cannot reached due to SO part.; ordrng 2 WPW10314173 (Drum support)s
We serviced a
WHIRLPOOL DRYER
Model WED6620HW0
Near Gloucester Point, VA 23062
Justin W.
Job Details:
12/01/2022
stacked unit low clearance. replaced control and ui tested unit working as designed
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT148FZDM04
Near Sterling, VA 20164
Jason A.
Job Details:
12/01/2022
CX complaint FRIDGE door sw broken. Verified issue. Replaced switch & test light works > JJ
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS588FIHZ00
Near Frederick, MD 21703
Ricardo S.
Job Details:
12/01/2022
Replaced freezer door.. unit tested and dispenser working ok
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRF736SDAM14
Near Laurel, MD 20723
Israel R.
Job Details:
12/01/2022
Installed starting device and capacitor. Unit is back to normal operations.
We serviced a
WHIRLPOOL DISHWASHER
Model WDT730PAHB0
Near Leesburg, VA 20175
Ricky E.
Job Details:
12/01/2022
customer stated that the lower rack had cracked wheels. verified issue unit will need wheel assys; ordrng 2 WPW10082868 (dishrack wheel)s
We serviced a
WHIRLPOOL RANGE
Model WFE550S0HW0
Near Leesburg, VA 20175
Ricky E.
Job Details:
12/01/2022
"customer stated that the unit was overjeating and giving an error of 6-1. verified issue and fnd falty broil relay at the control. when anything is chosen on the ui, the broil element will turn on.. need part...; ordrng 1 W11317859 (cntrl-elec)"
We serviced a
KITCHENAID FREEZER
Model KRFF300ESS01
Near North Bethesda, MD 20852
Roberto I.
Job Details:
12/01/2022
"Replaced parts, and also used a clamp (w488878) from v/s. Cycled icemaker, it filled ok and didn't leak.; ordrng 1 w488878 (clamp (RI van stock)), used 1 w488878 (clamp) from stock"
We serviced a
WHIRLPOOL REFRIGERATOR
Model ED5PVEXWS00
Near Washington, DC 20002
Mitchell H.
Job Details:
12/01/2022
cx complaint unit not dispensing water well. instlled valve and tested. unit working as desinged. job completed.
We serviced a
MAYTAG FREEZER
Model MBF1958FEZ02
Near Eldersburg, MD 21784
Brian R.
Job Details:
12/01/2022
checked unit after last repair and no frost or ice on rails and drawer went in and out smooth as can be after adjusting and lubing rails. replaced gasket and heated to form unit. advised cx to leave door shut the next 20-30 min so gasket will form and set. unit checks. job complete.
We serviced a
WHIRLPOOL DISHWASHER
Model WDTA50SAHZ0
Near Silver Spring, MD 20902
Roberto I.
Job Details:
12/01/2022
"CX complaint no wash, upper rack broken. Ran test mode, found 4-3 and 7-1 errors. The wash notor didn't run. Confirmed 120V supplied by the control to the rmotor. Confirmed broken adjuster on upper rack. Ordering sump/motor assy W11087376 and adjuster kit W10712395. Return visit 12/12/22; ordrng 1 W11087376 (sump/motor assy) and 1 W10712395 (adjuster kit)"
We serviced a
JENN-AIR FREEZER
Model JBRFR30IGX00
Near Herndon, VA 20170
Jason A.
Job Details:
12/01/2022
CX complaint FRIDGE door handle loose & door not closing. Separated door panel & dighten door handle. Used locktite on screws. Test door for proper operation > JJ