Appliance Repair Brentwood Maryland
VIA INC Rated out of 5 stars based on 0 customer reviews
We serviced a
WHIRLPOOL WASHER
Model WFW5605MW0
Near Brentwood, MD 20722
Samuel R.
Job Details:
04/18/2023
cx complaint unit is not workimng and ends cyce early.checked unit and could confirm as unit would staert a cycle and turn off.reset unit and unit would still do it into 15mins into cycle leaving unit filled with water.unit will need a new control.unit is stacked and will need a 2nd tech.called office to order part and reschedule for 4/24 W11583890 1 tribles; ordrng 1 W11583890 (control) and 1 2ndtech (2nd tech)
We serviced a
MAYTAG WASHER
Model MHW5500FW1
Near Brentwood, MD 20722
Emmanuel R.
Job Details:
04/04/2023
"The nipple on the sensor is cracked, need to reorder parts.; schdld next appmnt for 4/14 FRI !"
We serviced a
AMANA WASHER
Model NTW4516FW3
Near Brentwood, MD 20722
Samuel R.
Job Details:
02/27/2023
cx complaint unit is barely washing and doesnt complete cycle.inspected unit and found unit to be barely agitating.ran a service cycel unit would barely spin.trued starting a cycle and unit would freeze.unt will need a new control and motor.W11170317 0 tribles W10890624 0 tribles; ordrng 1 W11170317 (main control) and 1 W10890624 (motor)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT318FMDB09
Near Brentwood, MD 20722
Shawn D.
Job Details:
02/06/2023
inspected unit and when opening fridge and freezer i get sick unit is really stinky. pulled unit out and checked back of unit and found lower side of drier connection hisses when you move it so i think leak is here unit is to stinky to go inside to check evaporator. installed parts fixed leak vacumed unit down and filled to recomended and started cooling. unit is good
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT318FMDB09
Near Brentwood, MD 20722
Samuel R.
Job Details:
02/01/2023
cx complaint unit is not cooling.inspected unit and found unit not cooling.no frost pattern on evap.checked amp draw and got 0 amps.checked voltage to starter and starter is getting 120v.called into office and talked with mm with my readings and seal system is needed.also advised cx to clean unit.unit willl need evap and compressor W11582592 2 tribles W11504415 28 tribles W11504431 25 tribles W11506619 31 tribles W11506635 53 tribles W11562258 1 tribles W11504419 15 tribles called into office to schedule; ordrng 1 W11582592 (compressor) and 1 W11504415 (coupler) and 1 W11504431 (coupler) and 1 W11506619 (coupler) and 1 W11506635 (coupler) and 1 W11562258 (evap) and 1 W11504419 (coupler) and 1 W11504449 (coupler)