Appliance Repair Largo Maryland

VIA INC Rated out of 5 stars based on customer reviews

We serviced a
MAYTAG DRYER
Model MED4500MW0
Near Largo, MD 20774
Shawn D.
Job Details: 09/11/2023
arrived cx said unit started working yesterday almost didnt have me look at unit. cx complaint unit keeps turning off and wont tunr back on someitmes while cycle is running or when trying to use dryer and everytime this happens the light wont turn on she resets breaker and light still wont trun on she says. inspected unit and is working and heating good at this time. removed lint screen to check vent both screws were loose so tighten screws then ran dryer with lint screen off and checked vent flow and is good. let unit run for 20 minutes and never turnd off off. i told cx to get electrican to get outlet/breaker checked sounds like power issue to unit or outlet issue unit sounds good and is working good at this time. cx said she will be getting electrican.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT106TFDB02
Near Largo, MD 20774
Shawn D.
Job Details: 07/25/2023
cx complaint unit stopped cooling again. inspected unit both section room temp. checked compresor area to find condenser line leaking again looks to be cacked. cut crack out and welded line on and tested no leaks. vacumed system down and filled with freon and started cooling again. unit is good to go
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT106TFDB02
Near Largo, MD 20774
Shawn D.
Job Details: 07/14/2023
"opened system and had no freon in the system, found condenser leaking the freon. replaced compressor condenser drier couples then vacumed unit down and fiulled to recomended and started cooling. unit is good to go; ordrng 1 w10143759 (uv drier SD V/S), used 1 w10143759 (uv drier SD V/S) from stock"
We serviced a
WHIRLPOOL WASHER
Model WTW8127LC0
Near Largo, MD 20774
Leon
Job Details: 06/29/2023
replaced door stike tested unit everything worked as it should
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT106TFDB02
Near Largo, MD 20774
Israel R.
Job Details: 06/22/2023
"Customer complaint unit is not cooling. Tested unit found compressor is not starting. Tested power to compressor got 120vAC, Tested capacitor and found 11.9 Fu. TEsted whinding onnthe compressor. REading 6.5 and 6.4 and 12.7 across.. Replaced starting device and now im getting .2 amps at the compressor and not frost pattern. THe unit is low of refrigerant or has a leak. Ordeirng compressor, drier, evap condenser, couplers, Lock rings and nitrogent kit for testing.; ordrng 1 W10843121 (filter dryer) and 1 W11504445 (coupler) and 1 W11504447 (coupler) and 1 W11580057 (compressor) and 1 W11504415 (Coupler) and 1 W11504430 (coupler) and 1 W11506619 (coupler) and 1 W11547180 (Starting device) and 1 Lockring (Lock ring) and 1 Nitrogentkit (nitrogent kit) and 1 W11579351 (Evaporator) and 1 W11504450 (coupler) and 1 W11506620 (coupler) and 1 W11577970 (condenser) and 1 W11504445 (Coupler) and 1 W11504432 (coupler) and 1 nitrogent (nit), used 1 W11547180 (START DEVICE VS IR) from stock"