JENN-AIR RANGE
Model JES1750FS1
Near Laurel, DE 19956
Michael E.
Job Details: 10/23/2023
"CX complaint: timer not working. Tested and verified complaint. When time is set it holds time but when start is pressed, the time on display changes. In tis case 35 min became 12 min. Ordering control. Cannot rescheduloe due to SO part; ordrng 1 W11295990 (control)"
We serviced a
KITCHENAID FREEZER
Model KRMF706EBS05
Near Laurel, DE 19956
Frederick R.
Job Details: 10/19/2023
Per prior visit I hooked gauges up ad unit was in a 30in vac still. Filled with 58g of R600a. Final low side pressure was at 10in vac. Informed CX 24-36hrs for unit to get to temps.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRT318FZDW10
Near Laurel, DE 19956
Michael E.
Job Details: 10/19/2023
CX complaint: RC gasket gaps. Inspected and verified complaint. I heated and reshaped gasket. Tested unit and it is now working properly. Job is complete
We serviced a
KITCHENAID FREEZER
Model KRMF706EBS05
Near Laurel, DE 19956
Frederick R.
Job Details: 10/12/2023
Arrived at unit and found 50deg in RC and 40 in FC. Took pressures and LS was 18in vac. Unit possibly filled with 134a by last service company but not sure. CX stated they had a big cylinder of refrigerant. On the trip I found no die at all on either evap or in compressor compartment. Evacuated system and filled with 150psi of nitrogen. Found no signs of leaks. Vac'd down to 30in . Went to fill with R600a and found threads on brand new can defective and wouod not secure to the scale to fill unit. Tried for over 30mins and had no luck. Cannot fill at this time but unit is vac'd down and holding at 30in vac. Spoke to Rich at WPTL documented with him the situation and let him know CX has food in fridge. Gave SR# to CX. Need to return asap to fill unit; saved tckt
We serviced a
KITCHENAID FREEZER
Model KRMF706EBS05
Near Laurel, DE 19956
Frederick R.
Job Details: 09/28/2023
CX complaint is no cool. Inspected/tested. Found 10 deg in FC and 38 in RC. Both temps taken with thermo coupler device. Pulled rear panel and found 120vac to inverter board and 5.7vdc to compressor. Compressor was running good and barely warm. Checked pressures and got10 vac in LS. Replaced drier with UV drier and pressure tested. Vac'd unit down to 30in and filled with 56g of R600a. Final LS pressure was at 12invac.Unit working properly. Informed CX it may take a few hrs to get to temps. Job is complete