We serviced a
WHIRLPOOL RANGE
Model WFE320M0JS3
Near Berwyn Heights, MD 20740
Sherwood
Job Details: 10/06/2023
i told cx i was here for the range and she said no and close the door.
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Berwyn Heights, MD 20740
Marc M.
Job Details: 10/04/2023
cx complaint unit not cooling after previous SS repair. inspected unit and found that the unit was unplugged at time of arrival. attached SS guages and checked pressures. with unit NOT running found low side at 22inch vacuum and high side at 0psi. restored power to unit and compressor started up with no problem and pressures moved to about 28 inch vacuum and still 0psi at high side. unit will need SS repair.; ordrng 1 W11546692 (evap) and 1 W11580057 (compressor) and 1 W11109499 (drier-tube)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Berwyn Heights, MD 20740
Justin S.
Job Details: 08/24/2023
CX complaint callback still not cooling - both sections - side by side refrigerator - internal lights - on. Replaced compressor and filled unit system with 2.4oz of r600a. Ijnstalled a UV dye filter. Unit is cooling good now; ordrng 1 WPW10143759 (dryer)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Berwyn Heights, MD 20740
Justin S.
Job Details: 08/24/2023
CX complaint callback still not cooling - both sections - side by side refrigerator - internal lights - on. Replaced compressor and filled unit system with 2.4oz of r600a. Ijnstalled a UV dye filter. Unit is cooling good now; ordrng 1 WPW10143759 (dryer)
We serviced a
WHIRLPOOL REFRIGERATOR
Model WRS315SDHZ08
Near Berwyn Heights, MD 20740
Davonte
Job Details: 08/07/2023
"cx complaint unit not cooling on both sides. confimred cx complaint. fc temps at 45 and rc temp at 80. inspecterd evap no frost pattern .called techline because we've been here multiple times for the same issue. explained to techline what worked we have done already, techline instisted that we have a SS job done.also when inpecting unit water flows slowly out of dispener, icemaker makes ice but very little. unit will need water valve as well.; ordrng 1 W11580057 (compressor) and 1 W11504415 (coupler) and 1 W11506619 (coupler) and 1 W10806346 (grommet) and 1 W11109499 (drier) and 1 W11504433 (coupler) and 1 W11547180 (relay) and 1 WPW10662129 (capacitor) and 1 W11546685 (valve)"